Design For Dignity
Retail Guidelines

Appendix

Accessible Toilets

Key retail requirements

AS 1428.1 has extensive detail on the design of accessible toilets. A summary of key points is provided below:

General

  • Water taps have lever handles, sensor plates or similar.
  • Lever handle has >50mm clearance to surface for easy grip with operable parts of the lever within 300mm from the front of the basin.
  • Hot on Left, Cold on Right OR Hot on Top, Cold on Bottom.
  • If hot water provided water comes from mixed spout.
  • Top of toilet seat to ground 460mm – 480mm.
  • Front of toilet bowl to back wall 790mm – 810mm.
  • Centre of toilet bowl to side wall 450mm – 460mm.
  • Seat not open fronted.
  • Load certified 150kg.
  • Seat contrast 30% luminance contrast to wall/ floor.
  • Lid remains upright when raised.
  • Have a backrest with load capability of 1100N.
  • Backrest width 350 to 400mm.
  • Backrest height 120 to 150mm from seat.
  • Flushing control (back) in zone height 600 to 1100, width 500mm from centre of toilet to non-wall side.
  • Flushing control (side) in zone height 600 to 1100, width centred on 300mm either side of toilet front.
  • Toilet paper holder 700mm from floor and not further than 300mm forward of toilet front.
  • Grab rails behind and to the side at a height 900 to 1100mm and rising in front to assist person rising.
  • Doors can be hinged or sliding but must be easy to open (less than 20 Newtons).
  • In use indicator / privacy latch with a bolt or catch and easy to grip snib which is at least 45mm from the centre of the spindle.

Washbasins

  • Wash basin to be provided at 800 to 830mm from floor.
  • Room underneath for footplate and knee clearance.

Fixtures and fittings

  • Mirror width >350mm. Height <900mm from floor and to >1850mm above floor.
  • Shelf adjacent to washbasin as part of vanity or separate fixture.
  • Soap, paper dispensers etc. 900 to 1100mm, one hand operation.
  • Clothes hanging device located between 1200 to 1350mm from floor.
  • Sanitary unit placed on wall side of toilet (as people use the other side to transfer from the wheelchair).

Showers (summary)

  • Two or more clothes hanging devices.
  • Self-draining, no kerbs or hobs.
  • Grab rails.
  • Shower head on flexi hose.

Circulation spaces

  • 2300 x 1900mm clear space.

Signage

  • Full signage specifications in the AS1428.1.